Logo Marienfeld




Counting chambers

Counting chambers are instruments for precise measuring. They are made of special optical glass and serve to determine the number of particles in liquids. Our counting chambers are manufactured in accordance with the DIN 12 847 and the German Calibration Ordinance.
In-vitro diagnostic applications generally require duplicate determinations. Consequently, our counting chambers for investigations of cell suspensions are equipped with 2 sets of grids. These counting grids are engraved into 2 ground and polished surfaces on the central ridge (=chamber bottom). This central ridge is located between 2 elevated also ground and polished ridges. A cover glass with a thickness of 0.4 mm is placed on top of these 2 outer ridges. This cover glass limits the examined volumes above the counting grids.

Dark-lined: standard counting chambers have counting grids which are engraved into the chamber bottom. Under the microscope the counting grid appears as a grid of dark lines.

Bright-lined: these counting chambers have counting grids which are engraved into an annealed metal coating, so that the counting grid appears as a grid of bright lines.


  Drawings of the counting grids can be found here
  Find here an information about working with counting chambers

 

Counting chambers, glass, DIN 12 847, with double net ruling, in transparent plastic box with 2 cover glasses 0.4 mm thickness, without clamps. The tolerance of the depth of chamber is + 2 %
           
suitable for in-vitro diagnostic applications, CE  

Counting chamber Malassez dark-lined

Counting chamber Fuchs-Rosenhtal bright-lined

Counting chamber Neubauer with clamps

         
dark line bright line      
         
Cat. No. Cat. No. system depth of chamber  
         
06 400 10 06 400 30 Neubauer-improved 0.1 mm  
06 401 10 06 401 30 Neubauer 0.1 mm  
06 402 10 06 402 30 Bürker 0.1 mm  
06 403 10 06 403 30 Bürker-Türk 0.1 mm  
06 404 10 06 404 30 Fuchs-Rosenthal 0.2 mm  
06 405 10 06 405 30 Nageotte 0.5 mm  
06 406 10 06 406 30 Malassez 0.2 mm  
06 407 10 06 407 30 Thoma 0.1 mm  
06 408 10 06 408 30 Thoma neu 0.1 mm  
         
         
not CE marked, only for sale and application outside EU  
         
dark line bright line system depth of chamber  
         
06 100 10 06 100 30 Neubauer-improved 0.1 mm  
06 101 10 06 101 30 Neubauer 0.1 mm  
06 102 10 06 102 30 Bürker 0.1 mm  
06 103 10 06 103 30 Bürker-Türk 0.1 mm  
06 104 10 06 104 30 Fuchs-Rosenthal 0.2 mm  
06 105 10 06 105 30 Nageotte 0.5 mm  
06 106 10 06 106 30 Malassez 0.2 mm  
06 107 10 06 107 30 Thoma 0.1 mm  
         
         
xx xxx x1   for counting chambers with 2 clamps please amend the catalogue number accordingly.  

 

Counting chambers Neubauer-improved, with V-slash for easily feeding the capillary gaps, double net ruling, suitable for in-vitro diagnostic applications, CE, in transparent plastic box with 2 cover glasses of 0.4 mm thickness, without clamps, tolerance of the depth of chamber is + 2 %
       
Cat. No.     Counting chambers with V-slash
     
06 500 10 dark line  
06 500 30 bright line  
     
     
     
     
     
     
     
     
     
     
     

 

Counting chambers Neubauer-improved with special depth (Petroff), double net ruling, dark-lined, in transparent plastic box with 2 cover glasses 0.4 mm thickness, without clamps, suitable for in-vitro diagnostic applications, CE
       
Cat. No. special depth (tol. + 1 µm)  
Counting chamber Petroff
     
06 420 10 0.01 mm  
06 421 10 0.02 mm  
     
     
     
     
     
     
     

 

Counting chambers acc. to Howard for investigation of fruit juice
       
Cat. No.    
Howard counting chamber
     
06 109 40 Counting chamber without cover glass, depth 0.1 mm, cell diameter approx. 18 mm int. and approx. 22 mm ext., with 2 counting lines 1402 µm apart  
     
03 330 01 Cover glass 25x40x0.4 mm, without mask, ground edges  
     
03 340 02 Cover glass 25x40x0.4 mm, with chromium mask to facilitate counting, with 5x5 holes of each 1.382 mm diameter  
       
       
06 110 40 Counting chamber without counting lines, without cover glass, depth 0.1 mm, cell diameter approx. 20 mm int. and approx. 26 mm ext.  
Howard counting chamber
     
03 340 01 Cover glass 33x33x1 mm, with metallic blue counting mask of 15x15 mm with 5x5 holes of each 1.382 mm diameter  
     
03 340 02 Cover glass 25x40x0.4 mm, with chromium mask to facilitate counting, with 5x5 holes of each 1.382 mm diameter  
     

 

Counting chambers acc. to McMaster
       
Cat. No.    
McMaster counting chamber
     
06 111 41 Counting chamber McMaster with 3 counting areas, for counting worm eggs, also suitable for liquid media, ground edges, rounded corners, cover glass with 3 counting grids of approx. 10x10 mm and 1.5 mm depth and 1 pair of clamps, size approx. 127x26 mm  
03 350 01 Spare cover glass approx. 80x18 mm  
     
06 112 40 Counting chamber McMaster with 2 counting areas of approx. 10x10 mm, for counting worm eggs, size approx. 75x32 mm, cover glass with 2 counting grids glued on 3 supports, depth approx. 1.5 mm  
     
     

 

Counting chambers acc. to Sedgewick-Rafter for counting particles and micro-organisms in 1 ml water or other transparent liquids, with cover glass. The cell of 50x20x1 mm is ruled in a 1 mm grid subdividing 1 ml into 1000 µl
       
Cat. No.    
Sedgewick-Rafter counting chamber
     
06 113 00 Counting chamber made of glass, with chromium deposited 1 mm grid image, for phase contrast use, ground and chamfered edges  
     
06 114 00 Counting chamber made of plastic  
     
03 360 00 Spare cover glass approx. 60x30x1 mm  
     
     
     

 

other products for counting blood cells:

 

 

Blood diluting pipettes
Cellcounter

 

 






Paul Marienfeld GmbH & Co. KG • Am Wöllerspfad 4 • 97922 Lauda-Königshofen